2 kontron ipmb-l link, 3 kontron mmc firmware upgrade status – Kontron AM4211 User Manual

Page 49

Advertising
background image

34

AM4211

www.kontron.com

5.1.2.1.2

Kontron IPMB-L Link

5.1.2.1.3

Kontron MMC Firmware Upgrade Status

Table 5-3:Kontron IPMB-L Link sensor

Event/Reading type
code

Sensor type

Sensor specific offset Event trigger

6Fh

C3h
OEM Kontron

IPMB-L Link

02h

IPMB-L Disable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting to

determine who is causing a bus hang)
7h = Undiagnosed Communication Failure

03h

IPMB-L Enable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting to

determine who is causing a bus hang)
7h = Undiagnosed Communication Failure

Table 5-4:Kontron MMC FW upgrade status sensor

Event/Reading type
code

Sensor type

Sensor specific offset Event trigger

6Fh

CAh
OEM Kontron

External

Component

Firmware Upgrade

Status

00h

Firmware Upgrade in Progress (no event)

01h

Firmware upgrade succeeded

02h

Firmware upgrade failed

Advertising