1 oem sensor description, 1 kontron fru info agent, Table 5-2 kontron fru info agent sensor – Kontron AM4211 User Manual

Page 48

Advertising
background image

33

AM4211

www.kontron.com

5.1.2.1

OEM Sensor Description

5.1.2.1.1

Kontron FRU Info Agent

Table 5-2:Kontron FRU info agent sensor

Event/Reading type
code

Sensor type

Sensor specific offset Event trigger

0Ah

C5h
OEM Kontron FRU

Info Agent

06h

Transition to degraded
Event Data 2 is used a bit flag error
Bit 7: unspecifiedError
Bit 6: notPresentError
Bit 5: multirecHeaderError
Bit 4: multirecDataError
Bit 3: timeout error
Bit 2: ipmcError
Bit 1: fruDataError
Bit 0: commonHeaderError
Event Data 3 is used a bit flag error
Bit 7: reserved
Bit 6: reserved
Bit 5: SetPortState Not Supported
Bit 4: SetPortState Error
Bit 3: reserved
Bit 2: reserved
Bit 1: reserved
Bit 0: Match Error, Not in single link matches

08h

Install Error
Event Data 2 is used a bit flag error
Bit 7: unspecifiedError
Bit 6: notPresentError
Bit 5: multirecHeaderError
Bit 4: multirecDataError
Bit 3: timeout error
Bit 2: ipmcError
Bit 1: fruDataError
Bit 0: commonHeaderError
Event Data 3 is used a bit flag error
Bit 7: SetClockState Not Supported
Bit 6: SetClockState Error
Bit 5: SetPortState Not Supported
Bit 4: SetPortState Error
Bit 3: Clock Internal Mismatch
Bit 2: Clock Match Error, Not a single clock matches
Bit 1: Internal mismatch
Bit 0: Match Error, Not in single link matches

Advertising