0 appendix, 1 eds file, Appendix – Rice Lake 920i Programmable HMI Indicator/Controller - ControlNet Interface User Manual

Page 16

Advertising
background image

12

ControlNet Installation and Programming Manual

4.0

Appendix

4.1

EDS File

The EDS file for the ControlNet adapter, shown below, is included on the CD that comes with the option. The
EDS file must be installed in the host device to enable communication with the indicator.

[File]

DescText = "AnyBus-S ControlNet";

CreateDate = 07-19-1999;

CreateTime = 11:11:51;

ModDate = 03-10-2004;

ModTime = 15:00:00;

Revision = 1.7;

[Device]

VendCode = 90;

VendName = "HMS Networks";

ProdType = 12;

ProdTypeStr = "Communication Adapter";

ProdCode = 1;

MajRev = 1;

MinRev = 50;

ProdName = "Anybus-S ControlNet";

Catalog = "Anybus-S ControlNet";

[Device Classification]

Class1 = 1_RSNetWorx_Adapter;

Class2 = ControlNet;

[Port]

Port1 = ControlNet_Redundant,

"Port A",

"20 F0 24 01",

2;

[Params]

Param2 =

0, $ first field shall equal 0

,, $ path size,path

0x0000, $ descriptor

199, $ data type : 16-bit Unsigned Integer

2, $ data size in bytes

"Output Size", $ name

"", $ units

"", $ help string

0,450,16, $ min,max,default data values

0,0,0,0, $ mult,dev,base,offset scaling not used

0,0,0,0, $ mult,dev,base,offset link not used

0; $ decimal places not used