4 controlnet interface specifications – Rice Lake 920i Programmable HMI Indicator/Controller - ControlNet Interface User Manual

Page 20

Advertising
background image

16

ControlNet Installation and Programming Manual

4.4

ControlNet Interface Specifications

Power Requirements

Bus Adapter Card with ControlNet Module, DC Power:

Supply voltage: 6 VDC, supplied by indicator bus
Typical current draw: 350 mA
Power consumption: 2.1 W

Indicators, Typical AC Load:

520

Power (TRMS):

3.51 W

Current (TRMS):

33.7 mA

820i

Power (TRMS):

2.18 W

Current (TRMS): 28.9mA

920i

Power (TRMS):

2.18 W

Current (TRMS):

28.9 mA

Communications Specifications

ControlNet RG-6 quad-shielded coaxial cable

Update rate is dependent on the configured baud rate and the
number of network nodes. Maximum update rate is 20–24 per
second.

Environmental Specifications

Temperature:

–10° to +40° C (14° to 104° F)

Conformance

The ControlNet Interface has been tested for conformance to
ControlNet communications adapter profile 12.

0007

B3:4

0

Swap Word 1

SWP

Swap
Source

#N7:4

Length

1

SWP

Word 1 Input I:9.5

0008

B3:4

1

Swap Word 2

SWP

Swap
Source

#N7:5

Length

1

SWP

Word 2 Input I:9.6

0009

B3:4

2

Swap Word 3

SWP

Swap
Source

#N7:6

Length

1

SWP

Word 3 Input I:9.7

0010

B3:4

3

Swap Word 4

SWP

Swap
Source

#N7:7

Length

1

SWP

Word 4 Input I:9.8

0011

END

Advertising