Rice Lake 920i Programmable HMI Indicator/Controller - ControlNet Interface User Manual

Page 5

Advertising
background image

Introduction

1

About This Manual

This manual provides information needed to install
and use the Rice Lake Weighing Systems ControlNet
Interface. The ControlNet

TM

Interface allows

520

,

720i

®

,

820i

®

, and

920i

®

indicators to communicate

with a master controller on a ControlNet network.

1

See the

520

,

720i

,

820i

, or

920i

Installation Manual

for additional installation information and detailed
descriptions of indicator functions.

The ControlNet Interface is installed inside the
indicator enclosure. Installation in NEMA 4X
stainless steel enclosures permits use in washdown
environments.

Some procedures described in this manual
require work inside the indicator enclosure.
These procedures are to be performed by
qualified service personnel only.

Authorized distributors and their employees
can view or download this manual from the
Rice Lake Weighing Systems distributor site
at

www.ricelake.com

.

1.0

Introduction

The ControlNet Interface returns weight and status information from a

520

,

720i

,

820i

, or

920i

indicator to a

master controller and provides limited control of indicator functions to the programmer. Indicator configuration
and calibration cannot be performed through the ControlNet Interface.

The ControlNet Interface functions as a Communications Adapter Device (profile 12) on a ControlNet network.
It acts as a group-two-only server on the network. At this time only one polled I/O connection is supported.

The master controller sends commands to the indicator through the ControlNet Interface by writing the
commands in the output command format. The ControlNet Interface returns the weight and status data in the
input command format. These actions are referred to as polled I/O. See Section 3.0 for descriptions of the polled
I/O commands.

1.

ControlNet™ is a trademark of ControlNet
International.