Figure 3-3. ladder logic for bit-swapping – Rice Lake 920i Programmable HMI Indicator/Controller - EtherNet/IP Interface User Manual
Page 12
<Local:1:I.Data.0>
0
1
2
(End)
Input_1
[
]
) (
B_Bit1
Control Bits
[
]
B_Bit1
Control Bits
Swap Byte
Source RLWS_EthernetIP:I.Data(0)
8192
Order Mode
HIGH/LOW
Dest DevNetIn1
32
SWPB
Swap Byte
Source RLWS_EthernetIP:I.Data(1)
3329
Order Mode
HIGH/LOW
Dest DevNetIn2
269
SWPB
Swap Byte
Source RLWS_EthernetIP:I.Data(2)
0
Order Mode
HIGH/LOW
Dest DevNetIn3
0
SWPB
Swap Byte
Source RLWS_EthernetIP:I.Data(3)
0
Order Mode
HIGH/LOW
Dest DevNetIn4
0
SWPB
[
]
B_Bit1
Control Bits
Swap Byte
Source DevNetCmd1
32
Order Mode
HIGH/LOW
Dest
RLWS_EthernetIP:O.Data(0)
8192
SWPB
SWPB
SWPB
SWPB
Swap Byte
Source DevNetCmd2
1
Order Mode
HIGH/LOW
Dest
RLWS_EthernetIP:O.Data(1)
256
Swap Byte
Source DevNetCmd3
0
Order Mode
HIGH/LOW
Dest
RLWS_EthernetIP:O.Data(2)
0
Swap Byte
Source DevNetCmd4
0
Order Mode
HIGH/LOW
Dest
RLWS_EthernetIP:O.Data(3)
0
Word 1 for the
Device Net Command
Word 2 of 4 for the
DevNet Command
Word 3 of 4 for the
DevNet Command
Word 4 of 4 for the
DevNet Command
8
520/720i/820i/920i EtherNet/IP Install & Programming Manual
Figure 3-3. Ladder Logic for Bit-swapping