520/720i/820i/920i EtherNet/IP Install & Programming Manual

Tertiary Units

Command: 18, 0x012
Parameter: Scale number

Command 18 switches the current format of the

specified scale to the tertiary units configured for that

scale, if available. This command is valid for the

920i

only.

Units Key Press (toggle units)

Command: 19, 0x013
Parameter: Scale number

Command 19 toggles the current format of the

specified scale to the next units configured for that

scale, as available.

Print Request

Command: 20, 0x014
Parameter: Scale number

Command 20 causes the indicator to execute a print

command for the current scale.

Display Accumulator

Command: 21, 0x015
Parameter: Scale number

Command 21 causes the value of the accumulator for

the specified scale to be displayed and returned. This

command is only valid if the accumulator for the

specified scale is enabled.

Clear Accumulator

Command: 22, 0x016
Parameter: Scale number

Command 22 clears the value of the accumulator for

the specified scale. This command is only valid if the

accumulator for the specified scale is enabled.

Push Weight to Accumulator

Command: 23, 0x017
Parameter: Scale number

Command 23 adds the net weight on the specified

scale to the value of the accumulator for the specified

scale. The scale must return to net zero between

accumulations. The indicator returns the accumulated

weight data for the specified scale. This command is

only valid if the accumulator for the specified scale is

enabled.

Return Gross as Integer

Command: 32, 0x020
Parameter: Scale number

Command 32 returns the gross weight value for the

specified scale as an integer.

Return Net as Integer

Command: 33, 0x021
Parameter: Scale number

Command 33 returns the net weight value for the

specified scale as an integer.

Return Tare as Integer

Command: 34, 0x022
Parameter: Scale number

Command 34 returns the tare weight value for the

specified scale as an integer.

Return Piece Count

Command: 35, 0x023
Parameter: Scale number

Command 35 returns the piece count value for the

specified scale. This command is valid only for the

520

indicator, and only if count mode is enabled.

Return Current Display as Integer

Command: 37, 0x025
Parameter: Scale number

Command 37 returns the weight value for the

specified scale as currently displayed. This may

include gross, net, tare, piece count, or accumulator

values, as enabled. On the

920i

, the weight value is

returned in the mode used to display a scale widget.

Return Accumulator as Integer

Command: 38, 0x026
Parameter: Scale number

Command 38 returns the accumulator value for the

specified scale. This command is only valid if the

accumulator for the specified scale is enabled.

Return Rate of Change as Integer

Command: 39, 0x027
Parameter: Scale number

Command 39 returns the current rate of change value

for the specified scale. This command is valid only for

the

720i

,

820i

,

920i

.

Return Peak as Integer

Command: 40, 0x028
Parameter: Scale number

Command 40 returns the net peak value for the

specified scale. This command is valid only for the

520

indicator, and only if the peak hold function is

enabled.

Set Batching State

Command: 95, 0x05F
Parameter: State (0 = off; 1 = auto; 2 = manual)

Command 95 sets the batching (BATCHNG)

parameter. Indicator status is returned with the current

weight for the last scale specified.

Batch Start

Command: 96, 0x060
Parameter: Scale number

Command 96 starts a batch program from the current

step after a stop, pause, or reset. Batch status is

returned with the current weight for the specified

scale.