0 appendix, 1 eds file, Appendix – Rice Lake 920i Programmable HMI Indicator/Controller - EtherNet/IP Interface User Manual

Page 22

Advertising
background image

18

520/720i/820i/920i EtherNet/IP Install & Programming Manual

5.0

Appendix

5.1

EDS File

The EDS file for the EtherNet/IP adapter, shown below, is included on the CD that comes with the option. The

EDS file must be installed in the host device to enable communication with the indicator.

[File]

DescText = "HMS AnyBus-Communicator EtherNet/IP";

CreateDate = 04-02-2003;

CreateTime = 14:40:00;

ModDate = 07-22-2003;

ModTime = 10:45:00;

Revision = 1.2;

[Device]

VendCode = 90;

VendName = "HMS Networks";

ProdType = 12;

ProdTypeStr = "Communication Adapter";

ProdCode = 1;

MajRev = 1;

MinRev = 17;

ProdName = "Anybus-C EtherNet/IP";

Catalog = "Anybus-C EtherNet/IP";

[Device Classification]

Class1 = EtherNetIP;

[Params]

Param1 =

0, $ first field shall equal 0

,, $ path size,path

0x0000, $ descriptor

0xC7, $ data type : 16-bit Unsigned Integer

2, $ data size in bytes

"Output Size", $ name

"", $ units

"", $ help string

0, 504, 16, $ min, max, default data values

0, 0, 0, 0, $ mult, dev, base, offset scaling not used

0, 0, 0, 0, $ mult, dev, base, offset link not used

0; $ decimal places not used

Param2 =

0, $ first field shall equal 0

,, $ path size,path

0x0000, $ descriptor

0xC7, $ data type : 16-bit Unsigned Integer

2, $ data size in bytes

"Input Size", $ name

"", $ units

"", $ help string

0, 504, 16, $ min, max, default data values

0, 0, 0, 0, $ mult, dev, base, offset scaling not used

0, 0, 0, 0, $ mult, dev, base, offset link not used

0; $ decimal places not used

[Connection Manager]