0 appendix, 1 eds file, Appendix – Rice Lake 920i Programmable HMI Indicator/Controller - EtherNet/IP Interface User Manual
Page 22
18
520/720i/820i/920i EtherNet/IP Install & Programming Manual
5.0
Appendix
5.1
EDS File
The EDS file for the EtherNet/IP adapter, shown below, is included on the CD that comes with the option. The
EDS file must be installed in the host device to enable communication with the indicator.
[File]
DescText = "HMS AnyBus-Communicator EtherNet/IP";
CreateDate = 04-02-2003;
CreateTime = 14:40:00;
ModDate = 07-22-2003;
ModTime = 10:45:00;
Revision = 1.2;
[Device]
VendCode = 90;
VendName = "HMS Networks";
ProdType = 12;
ProdTypeStr = "Communication Adapter";
ProdCode = 1;
MajRev = 1;
MinRev = 17;
ProdName = "Anybus-C EtherNet/IP";
Catalog = "Anybus-C EtherNet/IP";
[Device Classification]
Class1 = EtherNetIP;
[Params]
Param1 =
0, $ first field shall equal 0
,, $ path size,path
0x0000, $ descriptor
0xC7, $ data type : 16-bit Unsigned Integer
2, $ data size in bytes
"Output Size", $ name
"", $ units
"", $ help string
0, 504, 16, $ min, max, default data values
0, 0, 0, 0, $ mult, dev, base, offset scaling not used
0, 0, 0, 0, $ mult, dev, base, offset link not used
0; $ decimal places not used
Param2 =
0, $ first field shall equal 0
,, $ path size,path
0x0000, $ descriptor
0xC7, $ data type : 16-bit Unsigned Integer
2, $ data size in bytes
"Input Size", $ name
"", $ units
"", $ help string
0, 504, 16, $ min, max, default data values
0, 0, 0, 0, $ mult, dev, base, offset scaling not used
0, 0, 0, 0, $ mult, dev, base, offset link not used
0; $ decimal places not used
[Connection Manager]