2 ethernet/ip interface specifications – Rice Lake 920i Programmable HMI Indicator/Controller - EtherNet/IP Interface User Manual

Page 23

Advertising
background image

520/720i/820i/920i EtherNet/IP Install & Programming Manual - Appendix

19

Connection1 =

0x04010002, $ trigger & transport

$ 0-15 = supported transport classes (class 1)

$ 16 = cyclic (1 = supported)

$ 17 = change of state (0 = not supported)

$ 18 = on demand (0 = not supported)

$ 19-23 = reserved (must be zero)

$ 24-27 = exclusive owner

$ 28-30 = reserved (must be zero)

$ 31 = client 0 (don't care for classes 0 and 1)

0x44240405, $ point/multicast & priority & realtime format

$ 0 = O=>T fixed (1 = supported)

$ 1 = O=>T variable (0 = not supported)

$ 2 = T=>O fixed (1 = supported)

$ 3 = T=>O variable (0 = not supported)

$ 4-7 = reserved (must be zero)

$ 8-10 = O=>T header (4 byte run/idle)

$ 11 = reserved (must be zero)

$ 12-14 = T=>O header

$ 15 = reserved (must be zero)

$ 16-19 = O=>T point-to-point

$ 20-23 = T=>O multicast

$ 24-27 = O=>T scheduled

$ 28-31 = T=>O scheduled

,Param1,, $ O=>T RPI,Size,Format

,Param2,, $ T=>O RPI,Size,Format

,, $ config part 1 (dynamic assemblies)

,, $ config part 2 (module configuration)

"ABC-EIP IO Connection", $ connection name

"", $ Help string

"20 04 24 01 2C 96 2C 64"; $ exclusive output path

5.2

EtherNet/IP Interface Specifications

Power Requirements

Bus Adapter Card with EtherNet/IP Module, DC Power:

Supply voltage: 6 VDC, supplied by

520

/

920i

bus

Typical current draw: 270 mA
Power consumption: 1.62 W

Indicators, Typical AC Load:

520

Power (TRMS):3.51 W
Current (TRMS):33.7 mA

820i

Power (TRMS):2.18 W
Current (TRMS):28.9 mA

920i

Power (TRMS):2.18 W
Current (TRMS):28.9 mA

Communications Specifications

EtherNet/IP Network Communications:

Twisted-pair cabling at 10 or 100Mbps

Environmental Specifications

Temperature:

–10° to +40° C (14° to 104° F)

Conformance

The Anybus-S EtherNet/IP Interface has been tested by
ODVA’s independent test lab and found to comply with the
ODVA composite conformance test, revision 3.

The EtherNet/IP Interface has been found in accordance with
EMC directive 89/336/EEC for European standards EN
50081-2 and EN 61000-6-2.

Advertising