520/720i/820i/920i EtherNet/IP Install & Programming Manual

Read Tare as Float

Command: 290, 0x122
Parameter: Scale number

Command 290 returns the tare weight value for the

specified scale in floating-point format.

Read Piece Count as Float

Command: 291, 0x123
Parameter: Scale number

Command 291 returns the piece count value for the

specified scale in floating-point format. This

command is only valid for the

520

, and only if count

mode is enabled.

Read Current Display as Float

Command: 293, 0x125
Parameter: Scale number

Command 293 returns the weight value for the

specified scale as currently displayed in floating-point

format. This may include gross, net, tare, piece count,

rate-of-change, or accumulator values, as enabled. On

the

820i

/

920i

, the weight value is returned in the mode

used to display a scale widget.

Read Accumulator as Float

Command: 294, 0x126
Parameter: Scale number

Command 294 returns the accumulator value for the

specified scale in floating-point format. This

command is only valid if the accumulator for the

specified scale is enabled.

Read Rate of Change as Float

Command: 295, 0x127
Parameter: Scale number

Command 295 returns the current rate of change value

for the specified scale in floating-point format. This

command is only valid for the

820i

and

920i

.

Read Peak Value as Float

Command: 296, 0x128
Parameter: Scale number

Command 296 returns the net peak value for the

specified scale in floating-point format. This

command is only valid for the

520

, and only if the

peak hold function is enabled.

Set Setpoint Value as Float

Command: 304, 0x130
Parameter: Setpoint number
Value: Target value

Command 304 sets the target value for the specified

setpoint in floating-point format. This command is

only valid if the setpoint is enabled and requires a

target value.

Set Setpoint Hysteresis as Float

Command: 305, 0x131
Parameter: Setpoint number
Value: Hysteresis value

Command 305 sets the hysteresis value for the

specified setpoint in floating-point format. This

command is only valid if the setpoint is enabled and

requires a hysteresis value.

Set Setpoint Bandwidth as Float

Command: 306, 0x132
Parameter: Setpoint number
Value: Bandwidth value

Command 306 sets the bandwidth value for the

specified setpoint in floating-point format. This

command is only valid if the setpoint is enabled and

requires a bandwidth value.

Set Setpoint Preact as Float

Command: 307, 0x133
Parameter: Setpoint number
Value: Preact value

Command 307 sets the preact value for the specified

setpoint in floating-point format. This command is

only valid if the setpoint is enabled and requires a

preact value.

Read Setpoint Value as Float

Command: 320, 0x140
Parameter: Setpoint number

Command 320 returns the target value for the

specified setpoint in floating-point format. This

command is only valid if the setpoint is enabled and

requires a target value.

Read Setpoint Hysteresis as Float

Command: 321, 0x141
Parameter: Setpoint number

Command 321 returns the hysteresis value for the

specified setpoint in floating-point format. This

command is only valid if the setpoint is enabled and

requires a hysteresis value.

Read Setpoint Bandwidth as Float

Command: 322, 0x142
Parameter: Setpoint number

Command 322 returns the bandwidth value for the

specified setpoint in floating-point format. This

command is only valid if the setpoint is enabled and

requires a bandwidth value.

Read Setpoint Preact as Float

Command: 323, 0x143
Parameter: Setpoint number

Command 323 returns the preact value for the

specified setpoint in floating-point format. This

command is only valid if the setpoint is enabled and

requires a preact value.