2 ethernet/ip network connections, 3 led status indicators – Rice Lake 920i Programmable HMI Indicator/Controller - EtherNet/IP Interface User Manual

Page 8

Advertising
background image

4

520/720i/820i/920i EtherNet/IP Install & Programming Manual

.

Figure 2-6. EtherNet/IP 520 Backplate Cable Assembly

10. The indicator automatically recognizes all

installed option cards when the unit is

p o w e r e d o n . N o h a r d w a r e - s p e c i f i c

configuration is required to identify the

newly-installed EtherNet/IP interface to the

system.

DIP Switch Function

Setting any one of the DIP switches to the ON

position will set a static IP address when the indicator

i s p o w e r e d u p . T h i s I P a d d r e s s w i l l b e

192.168.0.XXX where the XXX = DIP switch setting.

Example: If switch #8 is ON, and the rest are OFF, the

static IP address will be 198.168.0.1. If switch #7 is

ON and the rest are OFF, the IP address will be

192.168.0.2.

2.2

EtherNet/IP Network Connections

Feed the EtherNet/IP network cable through the

indicator cord grip. Allow enough cable for routing

along inside of enclosure to connector on the

EtherNet/IP module. Connect network cables to

connector on the EtherNet/IP module (see Figure 2-4),

then use cable ties to secure network cables to the

cable tie mounts.

Note

To configure an IP Address, refer to
Section 3.1 on page 6.

2.3

LED Status Indicators

An LED array on the EtherNet/IP module provides

status info rmation fo r tro ub le sho oting (se e

Figure 2-7):

• LED 1 provides status about the link
• LED 2 provides status information about the

EtherNet/IP module

• LED 3 provides network status
• LED 4 flashes whenever a packet is sent or

received

1

2

3

4

Activity

Module status

Link status

Network status

Figure 2-7. EtherNet/IP Status LED Module

LED 1: Link Status

Table 2-1. LED 1 Status

LED 1 Color

State

Description

Green

On

Module has a link

Off

Link not sensed

Table 2-2. LED 2 Status

LED 2 Color/State

Description

Steady off

No power to module

Steady green

Module operating correctly

Flashing green

Module not configured

Flashing red

Recoverable fault detected

Steady red

Internal error detected

Flashing red/green

Performing power-on self-test

Advertising