Rice Lake 920i Programmable HMI Indicator/Controller - EtherNet/IP Interface User Manual

Page 19

Advertising
background image

520/720i/820i/920i EtherNet/IP Install & Programming Manual - Commands

15

Batch Pause

Command: 97, 0x061
Parameter: Scale number

Command 97 pauses a batch program at the current

step. Batch status is returned with the current weight

for the specified scale.

Batch Reset

Command: 98, 0x062
Parameter: Scale number

Command 98 stops a batch program and resets it to

the first batch step. Batch status is returned with the

current weight for the specified scale.

Batch Status

Command: 99, 0x063
Parameter: Scale number

Command 99 returns the status of a batch. Batch

status is returned with the current weight for the

specified scale.

Lock Front Panel of Indicator

Command: 112, 0x070
Parameter: Scale number

Command 112 disables all the keys on the front panel

of the indicator. Indicator status is returned with the

current weight for the specified scale.

Unlock Front Panel of Indicator

Command: 113, 0x071
Parameter: Scale number

Command 113 re-enables all the keys on the front

panel of the indicator. Indicator status is returned with

the current weight for the specified scale.

Set Digital Output ON

Command: 114, 0x072
Parameter: Slot number
Value: Bit number

Command 114 sets the specified digital output ON

(active). Use slot number 0 for onboard digital

outputs. Indicator status is returned with the current

weight for the last scale specified.

Set Digital Output OFF

Command: 115, 0x073
Parameter: Slot number
Value: Bit number

Command 115 sets the specified digital output OFF

(inactive). Use slot number 0 for onboard digital

outputs. Indicator status is returned with the current

weight for the last scale specified.

Read Digital I/O

Command: 116, 0x074
Parameter: Slot number

Command 116 returns the status for all digital I/O in

the specified slot in words 3and 4 (On the

520

, status

is returned only for the digital inputs.) Use slot

number 0 for onboard digital I/O. Indicator status is

returned in the status area for the last scale specified.

Enable Bus Command Handler

Command: 128, 0x80
Parameter: None

Command 128 enables the bus command handler in a

user program in a

920i

indicator only. While this

handler is enabled, all other PLC commands are

disabled.

No Operation

Command: 253, 0x0FD
Parameter: Scale number

Command 253 provides a command to use between

operations, as necessary, without causing the indicator

to perform any action. Indicator status and weight for

the specified scale is returned.

Reset Indicator

Command: 254, 0x0FE
Parameter: None

Command 254 provides a command to remotely reset

the indicator. No data is returned.

Return Status and Current Weight as Float

Command: 256, 0x100
Parameter: Scale number

Command 256 returns the status and weight of the

specified scale in floating-point format, without

changing the display. This command also causes the

format-independent commands to return a value in the

floating-point format.

Set Tare as Float

Command: 268, 0x10C
Parameter: Scale number
Value: Tare weight

Command 268 enters a tare for the scale selected in

floating-point format. The indicator returns the tare

weight as taken, or 0 for no tare.

Read Gross Weight as Float

Command: 288, 0x120
Parameter: Scale number

Command 288 returns the gross weight value for the

specified scale in floating-point format.

Read Net Weight as Float

Command: 289, 0x121
Parameter: Scale number

Command 289 returns the net weight value for the

specified scale in floating-point format.