Rice Lake 880 Performance Series Panel Mount Indicator/Controller - Modbus TCP Interface Option Installation and Programming Manual User Manual

Page 10

Advertising
background image

6

Modbus Interface Installation and Programming Manual

14. Once the module is properly seated, tighten the screws on the front to

0.25Nm using a T8 Torx bit (PN 158183, not included), to secure the module
to the option card. .

Figure 2-8. Secure Module to Option Card

15. Slide backplate with boards into enclosure, ensure that each board is seated

correctly in the grooves of the enclosure.

Ensure the enclosure is in the upright position, otherwise the connector
for the display will not align with the front cutcut. The DIN Rail clips will
be at the bottom.

Figure 2-9. Boards Installed in Controller Assembly Enclosure

16. Reassembly control box to the DIN rail.
17. Reconnect all connectors to the back of the controller assembly.
18. Reconnect power to the indicator.

The indicator automatically recognizes all installed option cards when the unit is
powered on. No hardware-specific configuration is required to identify the newly-
installed card to the system.

Tighten Screws

Note

Ensure boards are
seated properly in
the grooves of the
enclosure.

Corner screws

Din Rail Clip

Advertising