22 Modbus Interface Installation and Programming Manual

Set Setpoint Value as Float

Command: 304, 0x130
Parameter: Setpoint number
Value: Setpoint value

Command 320 sets the setpoint value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
setpoint value. Batch status is returned in place of the indicator status.
Set Setpoint Hysteresis as Float

Command: 305, 0x131
Parameter: Setpoint number
Value: Hysteresis value

Command 305 sets the hysteresis value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
hysteresis value. Batch status is returned in place of the indicator status.
Set Setpoint Bandwidth as Float

Command: 306, 0x132
Parameter: Setpoint number
Value: Bandwidth value

Command 306 sets the bandwidth value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
bandwidth value. Batch status is returned in place of the indicator status.
Set Setpoint Preact as Float

Command: 307, 0x133
Parameter: Setpoint number
Value: Preact value

Command 307 sets the preact value for the specified setpoint in floating-point format.
This command is only valid if the setpoint is configured and requires a preact value.
Batch status is returned in place of the indicator status.
Read Setpoint Value as Float

Command: 320, 0x140
Parameter: Setpoint number

Command 320 returns the target value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a target
value. Batch status is returned in place of the indicator status.
Read Setpoint Hysteresis as Float

Command: 321, 0x141
Parameter: Setpoint number

Command 321 returns the hysteresis value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
hysteresis value. Batch status is returned in place of the indicator status.
Read Setpoint Bandwidth as Float

Command: 322, 0x142
Parameter: Setpoint number

Command 322 returns the bandwidth value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a
bandwidth value. Batch status is returned in place of the indicator status.
Read Setpoint Preact as Float

Command: 323, 0x143
Parameter: Setpoint number

Command 323 returns the preact value for the specified setpoint in floating-point
format. This command is only valid if the setpoint is configured and requires a preact
value. Batch status is returned in place of the indicator status.