Rice Lake 880 Performance Series Panel Mount Indicator/Controller - Modbus TCP Interface Option Installation and Programming Manual User Manual

Page 25

Advertising
background image

Commands 21

No Operation

Command: 253, 0x0FD
Parameter: Scale number

Command 253 provides a command to use between operations, as necessary, without
causing the indicator to perform any action. Indicator status and weight for the
specified scale is returned.
Reset Indicator

Command: 254, 0x0FE
Parameter: None

Command 254 provides a command to remotely reset the indicator. No data is
returned.
Return Status and Current Weight as Float

Command: 256, 0x100
Parameter: Scale number

Command 256 returns the status and weight of the specified scale in floating-point
format, without changing the display. This command also causes the format-
independent commands to return a value in the floating-point format. Returns current
weight at a floating-point format.
Enter Tare as Float

Command: 268, 0x10C
Parameter: Scale number
Value: Tare weight

Command 268 enters a tare for the scale selected in floating-point format. The
indicator returns the tare weight as taken, or 0 for no tare.
Read Gross Weight as Float

Command: 288, 0x120
Parameter: Scale number

Command 288 returns the gross weight value for the specified scale in floating-point
format.
Read Net Weight as Float

Command: 289, 0x121
Parameter: Scale number

Command 289 returns the net weight value for the specified scale in floating-point
format.
Read Tare as Float

Command: 290, 0x122
Parameter: Scale number

Command 290 returns the tare weight value for the specified scale in floating-point
format.
Read Current Display as Float

Command: 293, 0x125
Parameter: Scale number

Command 293 returns the weight value for the specified scale as currently displayed
in floating-point format. This may include gross, net, tare, or accumulator values, as
enabled. The weight value is returned in the mode used to display a scale widget.
Read Accumulator as Float

Command: 294, 0x126
Parameter: Scale number

Command 294 returns the accumulator value for the specified scale in floating-point
format. Batch status is returned in place of the indicator status.