Commands 19

Display Accumulator

Command: 21, 0x015
Parameter: Scale number

Command 21 causes the value of the accumulator for the specified scale to be
displayed and returned. This command is only valid if the accumulator for the
specified scale is enabled.
Clear Accumulator

Command: 22, 0x016
Parameter: Scale number

Command 22 clears the value of the accumulator for the specified scale. This
command is only valid if the accumulator for the specified scale is enabled.
Push Weight to Accumulator

Command: 23, 0x017
Parameter: Scale number

Command 23 adds the net weight on the specified scale to the value of the
accumulator for the specified scale. The scale must return to net zero between
accumulations. The indicator returns the accumulated weight data for the specified
scale. This command is only valid if the accumulator for the specified scale is
enabled.
Return Gross as Integer

Command: 32, 0x020
Parameter: Scale number

Command 32 returns the gross weight value for the specified scale as an integer.
Return Net as Integer

Command: 33, 0x021
Parameter: Scale number

Command 33 returns the net weight value for the specified scale as an integer.
Return Tare as Integer

Command: 34, 0x022
Parameter: Scale number

Command 34 returns the tare weight value for the specified scale as an integer.
Return Current Display as Integer

Command: 37, 0x025
Parameter: Scale number

Command 37 returns the weight value for the specified scale as currently displayed.
This may include gross, net, tare, or accumulator values, as enabled.
Return Accumulator as Integer

Command: 38, 0x026
Parameter: Scale number

Command 38 returns the accumulator value for the specified scale. This command is
only valid if the accumulator for the specified scale is enabled.
Set Batching State

Command: 95, 0x05F
Parameter: State (0 = off; 1 = auto; 2 = manual)

Command 95 sets the batching (BATCHNG) parameter. Indicator status is returned
with the current weight for the last scale specified.
Batch Start

Command: 96, 0x060
Parameter: Scale number

Command 96 starts a batch program from the current step after a stop, pause, or reset.
Batch status is returned with the current weight for the specified scale.