16 Modbus Interface Installation and Programming Manual

Bit-0 Errors

• PLC command failed to execute.
• No configuration has taken place.
• Scale parameter is out of range.
• Print error has occurred.
• Load error has occurred.
• Memory error has occurred.
• Analog to digital converter error.
• Tare error.
• Scale over range error.
• Scale under range error.
• Non-recoverable configuration store error.
• Indicator in configuration mode.

4.2.3

Value

Weight data is returned to the master in the third and fourth words of the input
command format, depending on the command and the value type. The weight data
returned is the displayed weight after the command is executed, unless the command
specifies otherwise.
A negative value will be returned in the two’s compliment format.

Word 2

Bit

Batch Function Status Data

Value=0

Value=1

00

Digital input 4 OFF

Digital input 4 ON

01

Digital input 3 OFF

Digital input 3 ON

02

Digital input 2 OFF

Digital input 2 ON

03

Digital input 1 OFF

Digital input 1 ON

04

Batch not paused

Batch paused

05

Batch not running

Batch running

06

Batch not stopped

Batch stopped

07

Alarm OFF

Alarm ON

08

Setpoint number

09

10

11

12

13

Not used

14

Integer data

Floating point data

15

Positive weight

Negative weight

Table 4-5. Batch Function Status Data Format