Digital i/o ports, Serial ports – Rice Lake 920i Bulkweigher 107 - 108 - 109 User Manual
Page 13
Advertising
Option Cards
9
Digital I/O Ports
Table 2-3. Digital I/O Assignments
Slot
Bit
Description
Input/Output
0
1
Start/resume
Input
0
2
E-Stop/run switch
0
3
End cycle button
0
4
System 107 shipping mode
0
5
System 108 receiving mode
0
6
Manual mode abort
2
1
Fill gate closed
Input
2
2
Discharge gate closed
2
3
Lower surge hopper not full
2
4
Weigh hopper not overfilled
2
5
Printer online
2
6-9
Unused
Off
2
10
Slow cycle alarm (option)
Output
2
11
Gate alarm (option)
2
12
Scale overfill alarm (option)
2
13
Lower surge backup alarm (option)
2
14
Printer alarm (option)
2
15
Open fill gate
2
16
Open discharge gate
Serial Ports
Table 2-4. Serial Port Setup
Port
Input
Output
Setup
1
Open
Open
9600 baud
8 bit
None
2
Open
Open
115200 baud
8 bit
None
3
Command
Printer
9600 baud
8 bit
None
CR/LF
4
Command
Remote display
9600 baud
8 bit
None
CR/LF
Advertising