16

920i Flexweigh Systems Bulkweigher

The screen is displayed as in Figure 6-2

04/17/2012

02:25PM

SCALE #1

Exit

SCALE #1

Draft

Weight

0

Gross

Lb

Accum: (0) 0

Draft

Empty

Preact

Target

1000 lb

5 lb

OFF (0) lb

5000 lb

Discharge Gate Closed

Fill Gate Closed

Manual

Receiving

Empty
Weight

Preact

Weight

Target

Weight

.

Figure 3-2. Presets Softkeys

Press one of the softkeys and enter a desired weight value pressing

enter

to save that value.

3.10.1 Preact

Preact provides some scale overfill protection on the first draft of a cycle when the upper garner may be full and the
surge of flow on the first draft might be overwhelming. The preact value entered may be exceptionally large and is
the fixed value in effect on every first draft that occurs after pressing

Start

or after recovering from a stop by press-

ing

Resume

. On subsequent fills during the cycle, the preact self learns and makes large auto preact adjustment cor-

rections of 50% whenever the final fill weight is more than 2% of the fill weight preset.

Press the

Preact Mode

softkey to access that screen. Select a preact option. Press the

Preact Mode

softkey to toggle

between

ON, OFF,

and

LEARN

.

Enter the preact weight by pressing the

Preact Weigh

t softkey. Press

enter

to save that selection.

Advertising