1 preact, Preact, Accum: (0) 0 – Rice Lake 920i Bulkweigher 107 - 108 - 109 User Manual
Page 20
16
920i Flexweigh Systems Bulkweigher
The screen is displayed as in Figure 6-2
04/17/2012
02:25PM
SCALE #1
Exit
SCALE #1
Draft
Weight
0
Gross
Lb
Accum: (0) 0
Draft
Empty
Preact
Target
1000 lb
5 lb
OFF (0) lb
5000 lb
Discharge Gate Closed
Fill Gate Closed
Manual
Receiving
Empty
Weight
Preact
Weight
Target
Weight
.
Figure 3-2. Presets Softkeys
Press one of the softkeys and enter a desired weight value pressing
enter
to save that value.
3.10.1 Preact
Preact provides some scale overfill protection on the first draft of a cycle when the upper garner may be full and the
surge of flow on the first draft might be overwhelming. The preact value entered may be exceptionally large and is
the fixed value in effect on every first draft that occurs after pressing
Start
or after recovering from a stop by press-
ing
Resume
. On subsequent fills during the cycle, the preact self learns and makes large auto preact adjustment cor-
rections of 50% whenever the final fill weight is more than 2% of the fill weight preset.
Press the
Preact Mode
softkey to access that screen. Select a preact option. Press the
Preact Mode
softkey to toggle
between
ON, OFF,
and
LEARN
.
Enter the preact weight by pressing the
Preact Weigh
t softkey. Press
enter