14

920i Flexweigh Systems Bulkweigher

3.2

ID#1 and ID#2 Softkeys

The ID keys allow an operator to log an extra data field. The ID softkeys can be either enabled or disabled and
appear on the main screen (see Figure 5-7) to allow the operator to enter more data, such as name. Press the

ID#1

or

ID#2

softkey and the following screen is displayed.

04/17/2012

02:17PM

SCALE #1

No

Enable ID#1

3

SCALE #1

Gross
Lb

Yes

ID #1: (Disabled)
ID #2: (Disabled)

Slow Cycle Time (sec): 45.00
Delay After Fill (sec): 3.0
Delay After Discharge (sec): 3.0
Discharge Delay (sec): 3.0
Subtotal Print: 3

Program: Express xxxx, PN

Setup Menu

Figure 3-1. ID Softkey Screen Display

Press

Yes

to Enable ID#1 or ID#2. If Yes is selected the operator is prompted to

Enter ID#1 Name

. Use the numeric

keypad on the indicator and press

enter

to save that ID name. Press

No

to disable ID#1 or ID#2.

3.3

Delay After Fill

The

Delay After Fill

softkey specifies the delay after fill in seconds to allow the scale to settle and the gate to

mechanically close. At the end of this time delay, the gate closed switch is checked. If not closed, the system enters
an error condition. No further operation is allowed until the condition is cleared. The default is 3.0 seconds. To
change the default, enter the new time and press

enter

to save the value.

3.4

Delay After Discharge

The

Delay After Discharge

softkey specifies the delay after discharge in seconds to allow the scale to settle and the

gate to mechanically close. At the end of this time delay, the gate closed switch is checked. If it is not closed, the
system enters an error condition. No further operation will be allowed until the condition is cleared. The default is
3.0 seconds. To change the default, enter the new time and press

enter

to save the value.

3.5

Discharge Delay

The

Discharge Delay

softkey specifies the length of time in seconds before the gate opens and the scale starts dis-

charging.

The default time is 3.0 seconds. To change the default, enter the new time and press

enter

to save the value.

3.6

Slow Cycle Time

Specifies the period of time allowed to complete a fill or discharge cycle. The purpose of the slow cycle timer is to
detect starved or blocked product flow. If a fill or discharge cycle is started that does not complete within the
selected slow cycle time period, a slow cycle alarm is displayed and a slow cycle alarm output is turned on.
The system remains in a slow cycle alarm state until the fill or discharge cycle does complete, until the end cycle
switch input, until the reset switch input, or until a manual mode switch input.

3.7

Draft Subtotals

Specifies the number of drafts between the subtotal printout.