2 regulatory mode functions – Rice Lake 920i Installation Manual V2.0 User Manual

Page 100

Advertising
background image

96

920i

Installation Manual

10.2 Regulatory Mode Functions

The function of the front panel

TARE

and

ZERO

keys depends on the value speciÞed for the REGULAT

parameter on the FEATURE menu. Table 10-4 describes the function of these keys for the NTEP, CANADA,
OIML, and NONE regulatory modes.

TARE

and

ZERO

key functions are conÞgurable when the REGULAT

mode is set to INDUST (see Table 10-5 on page 96).

Table 10-5 lists the subparameters available when conÞguring a scale using INDUST mode. The table includes
the default values of the INDUST subparameters and the effective (not conÞgurable) values used by the NTEP,
CANADA, OIML, and NONE regulatory modes.

REGULAT

Parameter Value

Weight on Scale

Tare in System

Front Panel Key Function

TARE

ZERO

NTEP

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

TARE

CANADA

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

no action

OIML

zero or negative

no

no action

ZERO

yes

CLEAR TARE

ZERO and CLEAR TARE

positive

no

TARE

ZERO

yes

TARE

ZERO and CLEAR TARE

NONE

zero or negative

no

TARE

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

CLEAR TARE

Table 10-4. TARE and ZERO Key Functions for REGULAT Parameter Settings

REGULAT / INDUST Parameter

REGULAT Mode

Parameter Name

Text Prompt

INDUST

NTEP

CANADA

OIML

NONE

SNPSHOT

Display or Scale weight source

DISPLAY

DISPLAY

DISPLAY

DISPLAY

SCALE

HTARE

Allow tare in display hold

NO

NO

NO

NO

YES

ZTARE

Remove tare on ZERO

NO

NO

NO

YES

NO

KTARE

Allow keyed tare with load on scale

NO

YES

NO

YES

YES

MTARE

Multiple tare action

REPLACE

REPLACE

NOTHING

REPLACE

REMOVE

NTARE

Allow negative tare

NO

NO

NO

NO

YES

CTARE

Allow CLEAR key to clear
tare/accumulator

NO

YES

NO

NO

YES

PRTMOT

Allow print while in motion

NO

NO

NO

NO

YES

PRTPT

Add PT to keyed tare print

NO

NO

YES

YES

NO

PRTHLD

Print during display hold

NO

NO

NO

NO

YES

HLDWGH

Allow weigh during display hold

NO

NO

NO

NO

YES

MOTWGH

Allow weighment in motion

NO

NO

NO

NO

NO

Table 10-5. REGULAT / INDUST Mode Parameters, Comparison with Effective Values of Other Modes