Rice Lake 920i Installation Manual V2.0 User Manual

Page 40

Advertising
background image

36

920i

Installation Manual

SOFTKEYS

<blank>
Time/Date
Display Tare
Display Accum
Display ROC
Setpoint
Batch Start
Batch Stop
Batch Pause
Batch Reset
Weigh In
Weigh Out
Truck Regs
Unit ID
Select Scale
F1–F10
Diagnostics

Use the Add and Remove softkeys to select softkeys to be displayed in weighing mode.

KYBDLK

OFF
ON

Keyboard lock. Specify ON to disable the keypad in normal mode.

ZERONLY

OFF
ON

Zero key only. Specify ON to disable all front panel keys except ZERO in normal mode.

PROMPTS

PROMPT1–
PROMPT60

Specify prompts for use in setpoint names. Prompts are referenced by the NAME
parameter under the SETPTS submenus; prompts can be shown on the display during
setpoint execution.

REGULAT

NTEP
CANADA
INDUST
NONE
OIML

Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.

• OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater

than zero. NONE allows tares to be acquired at any weight value.

• OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is

at no load. NONE allows tares to be cleared at any weight value.

• NTEP and OIML modes allow a new tare to be acquired even if a tare is already

present. In CANADA mode, the previous tare must be cleared before a new tare can be
acquired.

• NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net

mode as long as the current weight is within the specified ZRANGE. In OIML mode, the
scale must be in gross mode before it can be zeroed; pressing the ZERO key in net
mode clears the tare.

• INDUST provides a set of subparameters to allow customization of tare, clear, and print

functions in non-legal-for-trade scale installations. See Level 4 parameter descriptions
in Table 3-8 on page 39.

The value specified for this parameter affects the function of the front panel TARE and ZERO
keys. See Section 10.2 on page 96 for a complete description of TARE and ZERO key
functions for each of the regulatory modes.

REGWORD

GROSS
BRUTTO

Sets the term displayed when weighing in gross mode. Selecting BRUTTO replaces the
Gross annunciator with Brutto.

CONTACT

Allows specification of contact information for use in

iQUBE alert messages. See Level 3

submenu descriptions in Table 3-7 on page 38.

LOCALE

OFF
ON

Locale. Set this parameter ON to enable the LATUDE and ELEVAT parameters. Specifying
latitude and elevation of the scale site provides compensation for gravitational effects.
Attached scales must be recalibrated after changing this parameter from OFF to ON.

NOTE: Gravitational compensation settings do not affect

iQUBE

scales.

FEATURE Menu

Parameter

Choices

Description

Table 3-6. FEATURE Menu Parameters (Continued)

Advertising