46

920i

Installation Manual

4.0

Calibration

The

920i

can be calibrated using the front panel, serial commands, or

iRev

. Each method consists of the

following steps:

¥

Zero calibration

¥

Entering the test weight value

¥

Span calibration

¥

Optional Þve-point linearization

¥

Optional rezero calibration for test weights using hooks or chains

The following sections describe the calibration procedure for each of the calibration methods. See the

iQUBE

Installation Manual, PN 77224, for information about conÞguring

iQUBE

-attached scales.

Figure 4-1. Calibration (CALIBR) Submenu

4.1

Gravity Compensation

Gravity compensation for latitude and elevation is available for the

920i

. To calibrate with gravity compensation,

the LOCALE parameter under the FEATURE menu must be set ON, and the LATUDE (latitude) and ELEVAT
(elevation, in meters) parameters set before calibrating the indicator (see Figure 3-9 on page 34).

If the indicator is later installed at a different location, gravity compensation can be applied to a pre-calibrated
indicator by adjusting the LATUDE and ELEVAT parameters.

4.2

Front Panel Calibration

The CALIBR submenu (under the SCALES menu,
see Figure 4-2) is used to calibrate the

920i

. The zero,

span, and linear calibration point displays provide a
set of softkeys used speciÞcally for calibration
procedures:

Default

Restores the value to its default

+/–

Toggles to allow entry of negative or
positive values

Calibrate

Performs calibration for the selected
point

Millivolts

(or

Counts

)

Toggles between display of captured
A/D counts and captured millivolts
values; allows entry of calibration
values in mV or counts

Restore

Restores the value to the previously
saved value

Figure 4-2. WZERO Calibration Display

SCALES

SERIAL

FEATURE

PFORMT

SETPTS

DIG I/O

ALGOUT

VERS

SCALE 1

CALIBR

WZERO

WVAL

WSPAN

WLIN

REZERO

PT->4

PT->5

PT->1

PT->2

PT->3

Advertising