Rice Lake 920i Installation Manual V3.13 User Manual

Page 85

Advertising
background image

Setpoints

79

SETPTS Menu

Parameter

Choices

Description

Level 2 submenus

SETPT 1–
SETPT 100

OFF
GROSS
NET
–GROSS
–NET
ACCUM
ROC
+REL
–REL
%REL
RESREL
PAUSE
DELAY
WAITSS
COUNTER
AUTOJOG
COZ
INMOTON
INRANGE
BATCHPR
TIMER
CONCUR
DGIN
AVG
TOD
DELTA
CHKWEI
PLSCNT
PLSRAT
ALWAYS
NEVER
DINCNT

Specifies the setpoint kind.

GROSS, NET, –GROSS, –NET, ACCUM, ROC, +REL, –REL, %REL, RESREL. DIGIN,
DINCNT, AVG, and TOD setpoint kinds can be used as either batch or continuous
setpoints.

PAUSE, DELAY, WAITSS, COUNTER, AUTOJOG, DELTA, PLSCNT, ALWAYS, and
NEVER setpoint kinds can only be used in batch sequences.

COZ, INMOTON, INRANGE, BATCHPR, TIMER, CONCUR, PLSRAT, and CHKWEI
setpoint kinds can only be used as continuous setpoints.

See Table 8-1 on page 67 for more information about setpoint kinds.

BATCHNG

OFF
AUTO
MANUAL

Batching enable. Set to AUTO or MANUAL to allow a batch sequence to run.
MANUAL requires a BATSTRT digital input, BATSTART serial command, Batch Start
softkey, or the StartBatch function in an

iRite

program before the batch sequence

can run. AUTO allows batch sequences to repeat continuously.

Table 8-2. Setpoint Menu Parameters

Advertising