14

CLS Series Service Manual

Bottom Board Information

Figure 3-4. Inside of Junction Box - Bottom Board

The junction box has two boards within the box. To access the bottom board, remove the screws that hold the top
board in place and flip the top board up and back out of the way as the wires that connect the top and bottom
boards are long enough to acommodate this. The bottom board which is shown in Figure 3-4 connects the wiring
for both load cells one and two. Table 3-1 lists the wiring assignments for the bottom board.

9. Reconnect the wires to the bottom board per Figure 3-4, Figure 3-5, and Table 3-1 listed below.

J4 Wiring Connector

(Cell #1 - the left cell as viewed from the

forklift drivers seat)

J4 Function

1

+ SIGNAL

2

- SIGNAL

3

+ EXCITATION

4

- EXCITATION

5

SHIELD

J5 Wiring Connector

(Cell #2 - the right cell as viewed from the

forklift drivers seat)

J5 Function

1

+ SIGNAL

2

- SIGNAL

3

+ EXCITATION

4

- EXCITATION

5

SHIELD

J8 Wiring Connector

(From the MS Connector)

J8 Function

1

+ V (Red)

2

- V (Black)

Table 3-1. Load Cell Wiring

J4 Loadcell
connector

J5 Loadcell connector