F4.0 PRINT MODE
d
Print output is disabled.
1
Print button latches the Print Request. Printing will occur when motion
ceases and scale is positive.
2
Print will occur if not in motion and positive at the time Print button
is pressed.
3
Auto print after motion has settled and positive weight is above the
value specified in F4.2 below has occurred.
F4.1 CONTINUOUS DATA FORMAT
d Continuous output disabled.
1 Status, weight, and tare data sent.
2 Z660 Scoreboard output.
3 Remote display, RD-IV, output.
4 Straight ASCII output only.
F4.2 WEIGHT CHANGE PERCENTAGE
The following values specify the percentage change of Full Scale Capacity
before the auto print latch is re-armed.
Options: 5, 10, 15, 20, 25%
F4.3
MINIMUM PRINT
Digits above zero before auto print is latched.
Options: 0, 10, 20, 30