0 setup, 1 power connection – Rice Lake DWM-IV Digital Weighmeter Model 5 User Manual

Page 7

Advertising
background image

3.0 Setup

Set up of the Model 5 requires that the unit be provided with power via the TB1

connector and connected to the load cell via the TB3 connector. The optional connector,

TB2, is used if a serial printer/computer is supplied.

3.1 Power Connection

Refer to the Model 5 circuit board drawing in Section 8.0 BOARD LAYOUT

to locate the power connector TB1, the RS232 connector TB2, and the load cell

connector TB3. Remove the back panel by unscrewing the six screws around the

perimeter. Push the wall transformer cable through the rightmost strain relief,

SR1. Push the load cell cable through the leftmost strain relief, SR3. Using the

supplied three position terminal block, attach the three conductor power supply

cable wires using a small, flat-blade screwdriver according to the following color

codes:

Wall Transformer

P/N AA-091AG

TB1

Wall Transformer

P/N 48A-9-1000

TB1

BROWN

+IN

RED

+IN

GREEN

GND

WHITE

GND

BLUE

-IN

BLACK

-IN

Ensure that the Green or White wire from the wall transformer is always connected

to the GND terminal as this connection is the safety earth conductor. The unit

becomes grounded or earthed by plugging the wall transformer into a properly

wired three terminal wall receptacle. Never defeat the ground connection in the

interest of safety and noise rejection. Insert the power terminal onto TB1 of the

Model 5 circuit board.

Advertising