9750a – Rice Lake MSI-9750A CellScale RF Portable Indicator User Manual

Page 12

Advertising
background image

Page 12 MSI-9750A RF Remote Indicator • User Guide

9750A

HANDHELD RF REMOTE INDICATOR for

C

ELL

S

CALE

®

MODEM SETTINGS v2.05

1 Network Address 17

2 CS Address 17

3 My Address 57

4 Transmit Power HI

5 Timeout 1Øs

6 Advanced Settings

7 Save Settings Now

NETWORK ADDRESS

ESC exits no change

ENTER saves value

0-9 replaces value

17

min = 0, max = 63

^ incs, v decs value

CELLSCALE ADDRESS

ESC exits no change

ENTER saves value

0-9 replaces value

17

min = 5, max = 251

^ incs, v decs value

MY ADDRESS

ESC exits no change

ENTER saves value

0-9 replaces value

57

mmin = 5, max = 251

^ incs, v decs value

TIMEOUT THIS NETWORK

ESC exits no change

ENTER saves value

0-9 replaces value

min = 1, max = 1800

^ incs, v decs value

4 Transmit Power HI

4 Transmit Power MED

Saves Settings to Memory

Shortcut

4 Transmit Power LO

See Advanced Settings

MODEM SETTINGS v2.05

NETWORK ADDRESS

CELLSCALE ADDRESS

MY ADDRESS

TIMEOUT THIS NETWORK

RF NETWORK SETUP

The 9750A is a RF Modem connected device. The RF Modem requires setup to connect to one or more CellScales.

The 9750A stores information for all 64 possible networks. Each network setting can be modifi ed with the “Modem

Settings Menu”.

[1]

NETWORK ADDRESS – Sets the primary network

address number. Set this number to match the Network

number of the CellScale master the 9750A must com-

municate to. Ranges from 0 to 63.

[2]

CS ADDRESS – Sets the primary master CellScale ID

number. This number must match the Source Address

number of the primary master CellScale. Ranges from

5 (default) to 251. This number is usually 5.

[3]

MY ADDRESS – Any 9750A unit in a given Network

must have a unique ID number. Enter up to three digits

to designate the 9750A ID number. Ranges from 5 to

251. Make sure no other devices have this same number.

Other devices that must have unique numbers are 9020

Modems, 3750CS Indicators, and 9300 and/or 6260CS

crane scales used as slave units.

[4]

TRANSMIT POWER – Sets the RF power level between

10 mW (Lo), 63 mW (Med), and 250 mW (Hi). In most

applications power should be set to High. Reduced

energy can reduce the size of the coverage / interfer-

ence zone which may be desirable for multiple-network

applications. Always check for adequate range coverage

when using the Low setting. Only a minor improvement

in battery life (~10%) is achieved by using the Lo set-

ting.

[5]

TIMEOUT – Sets the time in seconds (0-1800) that the

9750A will wait for data from the CellScale Master. The

display will blank out if no data is received within this

time period. MSI recommends at least a 10 second time

out period to handle small lapses in transmissions. The

system defaults to 10 seconds.

[6]

ADJUST MODEM – Advanced features settings of the

Modem. See “ADJUST MODEM MENU” on the fol-

lowing page. This line also shows the fi rmware version

of the RF Modem (v2.0x).

[7]

SAVE SETTINGS NOW – Commits the settings to the

Modems Memory. The Modem settings will be automati-

cally saved at power down if changed.

SCAN NETWORK – Setting the Scan Network ON places

the network in the list of addresses reached by pressing

the ADDRESS key. Setting the Scan Network OFF still

allows you to pre confi gure the network settings, but the

Network will not be in the list of available networks.

Advertising