ADVANCED MODEM SETTINGS

The “ADVANCED SETTINGS’ menu provides access to some of the advanced features of the 9750A’s RF

Modem. These features are not usually needed and should be left to defaults.

1 Lock Out Key Ø

2 802.11 Avoid OFF

3 Scan Network OFF

4 Reranging 652.7 sec

Signal Strength 13Ø

Modem Ser. # ШШ-Ш2-46

ESC exits no change

ENTER saves value

Ø-9 replaces value

Ø

min = Ø, max = 255

^ incs, v decs value

1 OFF, FCC/ETSI LEGAL

2 Bands 1 & 2

3 Bands 3 & 4

4 Bands 5 & 6

5 Bands 7 & 8

6 Bands 9 & 10

7 MORE 1/2

ESC exits no change

ENTER saves value

Ø-9 replaces value

652

min = Ø, max = 655

^ incs, v decs value

3 Scan Network OFF

3 Scan Network ON

802.11b AVOIDANCE

1 Bands 11&12, France

2 Bands 1 & 10 to 12

3 Bands 1 to 6

4 Bands 6 to 12

5 Bands 1 to 3 & 11

7 MORE 2/2

7

ADVANCED SETTINGS

LOCK OUT KEY

802.11b AVOIDANCE

802.11b AVOIDANCE

RERANGING PERIOD, SEC

1) Lock Out Key – For added security in environments

where other CellScale modems are operating on the

same network, a Lock Out Key can be set which will

prevent modems from communicating. The Lock Out

key must also match in the master CellScale Modem.

DO NOT change this number from 0 unless all modem

elements are also changed as this will cause severe com-

munications problems.

2) 802.11 Avoidance – The 9750As modem can be set to

minimize interference with 802.11b RF networks in

common use for computer networks. You must deter-

mine which band the 802.11b modem is operating on

and then select the corresponding band to avoid. The

second page also includes a setting making the cellscale

legal in France. The CellScale master must also have the

same setting. DO NOT change the setting in this menu

without corresponding changes in all CellScale devices

in the network.

3) Scan Network – When On, this feature adds Network

address information to a current networks list. If this

9750A is to be used on multiple networks, turn the

“Scan Network” “ON” every time you log onto another

network that you may want to go back to. Then using

the

ADDRESS

key, you can quickly scroll through all

stored networks.

4) Reranging – This feature sets the interval in which the

modem requests recomputation of the distance compen-

sation. The default is suitable for standard operation and

should not be altered.

The next line below Reranging gives a relative receive

signal strength. This value reports the relative signal

strength averaged over the last 10 hops. Larger values

indicate stronger signals.

The next line indicates the RF Serial Number of the