Rice Lake MSI-9750A CellScale RF Portable Indicator User Manual

Page 37

Advertising
background image

MSI CellScale

®

System • 9750A User Guide Page 37

MEASUREMENT SYSTEMS INTERNATIONAL

Firmware Version 5-XX for 2450 Modems

PASSWORD LOCKS

The Lock function allows the user to lock various setups and or functions to prevent unauthorized changing or

erasing of scale functions, features and statistical data. For security a lock password (1-14 characters) is used. Once

the MSI 9750A is locked the message “LOCKED” will appear whenever a locked function is tried. To temporarily

unlock a function, press any locked key, press

ENTER

, then enter the password followed by the

ENTER

key.

To lock or unlock all functions you must use the “PASSWORD LOCKS” menu.

SETUP SELECT MENU

1 Function Keys

2 Set Points

3 System

4 Password Locks

5 BarCode

6 Total

7 MORE 1/2

PASSWORD LOCKS

1 Change Password

2 Status LOCKED

3 Lock Mode

4 Lock Override OFF

Password is:

-Password-

LOCK MODE

1 Function Key Setup

2 Set Points

3 System Settings

4 Set Password Locks

5 Display Preview

6 Total Setup

7 MORE 8 BACK 2/3

LOCK MODE

1 Channel/Calibrate

2 Scale Display Line

3 RF Modem

4 Comm 1 & Strings

5 Product ID Codes

6 Tare Setup

7 MORE 8 BACK 3/3

LOCK MODE

1 Lock All

2 FUNCTION Keys

3 SETUP Key

4 TARE Key

5 NET/GROSS Key

6 ZERO Key

7 MORE 8 BACK 1/3

2 Status LOCKED

2 Status UNLOCKED

7

7

7

8

8

8

2 Status LOCK ON PWR

Len 0 F4 Menu

Max 14 ENT Save

Pos 1

NEW PASSWORD

1

SETUP SELECT MENU

PASSWORD LOCKS

LOCK MODE

LOCK MODE

LOCK MODE

4 Lock Override OFF

4 Lock Override ON

See General Text Editing

Procedure

ESC

!

SETUP

To enter the Password Locks Menu press

SETUP

then [

4]

.

[1]

Change Password – Used to change the password. Pressing

[1]

brings up a text entry screen. Use the

ALPHA

key and the

keypad to input any password. Passwords are case sensitive,

so pay attention to upper and lower case characters.

[2]

Status – Pressing the

[2]

key changes the status from

“LOCKED” to “UNLOCKED” to “LOCK ON PWR”. The

“LOCK ON PWR” mode leaves the 9750A unlocked until the

power has been cycled. This allows the primary operator to

complete all setups without having to enter the password over

and over. When completely fi nished with setups, cycle the

power and then the lock will be in effect.

Do not forget your password. The only way to unlock a

locked system without the proper password is to do a

complete reset (RESET ALL), which will cause you to lose

all setups. Make a note of it in a secure location.

[3]

Lock Mode – Press the

[3]

key to select features and functions

for password protection. There are 3 submenu select screens. Use

the

[7]

key to scroll through all lockable items. Press the number

key beside each item to select it for locking. For example, to

lock out the Setup key press

[3]

. The arrow will appear indicat-

ing the Setup Key will lock. After selecting all the lock items,

press

SETUP

to return to the “PASSWORD LOCKS” menu.

Tip: Use “Lock All” to lock every lockable feature. Then unlock any features you wish to remain
operational. Remember to look at all three screens using the 7 key. The CLR key will unlock all
functions while in the Lock Mode menu.

If you forgot your password
MSI provides a master unlock that will erase all operator setups and

require you to completely start from scratch. This procedure will not

erase calibration, which is stored in the CellScale, not the 9750A.

However, all display modes, text strings, system settings, etc., stored

in the 9750A, will be lost.

!

[3]

Date Mode – Pressing

[3]

changes the date mode from MM/DD/YY to DD-MM-YY.

[4]

Time Mode – Press

[4]

to change between 24 hour time or 12 hour time with AM/PM indication.

[5]

Daylite (sic) Saving – Press

[5]

to select the Daylight Saving mode. Select “ON” when in Daylight Savings

Time (adds 1 hour). Select “OFF” when not in Daylight Savings time. Select “AUTO” to allow the 9750A

to automatically enter into and out of daylight savings time (follows US rules). Set the daylight saving