Page 18 MSI-9750A RF Remote Indicator • User Guide

9750A

HANDHELD RF REMOTE INDICATOR for

C

ELL

S

CALE

®

1) Press the

CHANNEL

key

[F2]

. The weight display will temporarily display dashes while it

queries the CellScale for the next channel information.

2) Keep pressing the

CHANNEL

key as desired until the channel of interest is displayed.

To go to the previous channel in the list, press the ENTER key followed by the CHANNEL key. (This assumes the default for E2 has not
been altered)

1

F2

CHANNEL

2

F2

CHANNEL

TO SELECT THE DISPLAY CHANNEL

As mentioned above, the 9750A will access any channels setup in the CellScale. It does this with the “CHAN-

NEL” function. Use the

CHANNEL

key to step from channel to channel as dictated by the Scan list stored in the

CellScale. If the CellScale has only one scale channel defi ned, only 1 display mode is necessary. This is usually

®

®

the case for MSI-6260CS, MSI-9300 Crane Scales, and other single load cell systems. However, even single load

cell systems can have math channels defi ned to add functionality.
For systems with multiple scales attached to any given CellScale the setup procedure is:

1) Program the CellScale Scan List as required (see the CellScale Manual). It is recommended that each channel

is assigned a channel name to aid in identifying the scale in various display modes.

2) Optional, but recommended so you can readily identify which scale you are monitoring and controlling

– Program the display mode to show the Channel Name, or Channel Number, or both with the Display Setup

procedures in Section 7.

To Change the Scale Channel (Single Channel Display)

This example assumes F2 is in its default mode CHANNEL.

1) Using the numeric keys, input the number (1-32) corresponding to the desired channel in the

scan list.

This example finds the fourth entry in the scan list. If a requested channel does not exist in the scan list, this procedure is ignored by the

CellScale.

2) Press the

CHANNEL

key

[F2]

. The weight display will temporarily display dashes while it

queries the CellScale for the desired channel information.

1

4

JKL

2

F2

CHANNEL

To Change the Scale Channel Using Scan List Position (Single Channel Display)

Uses the CellScale’s Scan List Index Number to determine which channel to display.

To Change Scale Channel Using the Channel Number (Single Channel Display)

Uses the CellScale’s Channel Number to determine which channel to display.

1) Using the numeric keys, input the number corresponding to the desired channel

number. Use the decimal point as the channel-subchannel separator.

This example finds channel 6-1, a math channel. If a requested channel does not exist in the scan list, this procedure

number. Use the decimal point as the channel-subchannel separator.

number. Use the decimal point as the channel-subchannel separator.

is ignored by the CellScale.

2) Press the

CHANNEL

key

[F2]

. The weight display will temporarily display dashes

while it queries the CellScale for the desired channel information.

1

6

PQR

DISPLAY

EXIT

1

ABC

2

F2

CHANNEL

MULTI-CHANNEL SYSTEMS

In CellScale systems with multiple channels, you can choose to see more than one channel at a time (See Display

Setup in Section 7). In order to zero, tare, or totalize with channels in a multiple channel display, you must fi rst

select the channel to operate on. This is referred to as the “Active” channel, because this is the only channel that

any scale function can be performed on.
To Select the Active Channel (multi-channel display)

1) Highlight the channel you wish to make Active by pressing the UP (

^

) or DOWN (

v

) cursor keys.

2) Once highlighted you can Zero the channel, set and clear Tare, and switch between Net and Gross with the

NET/GROSS

key, just press the appropriate key. For Total, View Total, Statistics and other ID functions,

you must switch the display to the single channel display by pressing

DISPLAY

.

To Change a Channel in the Multi-Channel Display

1) Highlight the channel you wish to change by pressing the UP (

^

) or DOWN (

v

) cursor keys.

2) Once highlighted enter the scan list position (1-32) or the channel number (1-1 to 6-32 using the decimal