Rice Lake SURVIVOR PL Rail Scale User Manual

Page 14

Advertising
background image

10

Survivor

®

PL

Installation Manual

Be certain each load cell grounding strap is securely connected to the top plate and bottom plate of each load cell

mount. There should be metal-to-metal contact with no presence of paint or grout. This strap is designed to channel

power surges on the deck around—rather than through—the load cell to ground.

Grounding
Strap

Figure 3-2. Grounding Strap on Load Cell Mount

These, and all, ground connections must be torqued to a specified value and retorqued at regular service intervals.

A thick coating of anti-oxidant grease should be maintained on all ground connections to prevent corrosion.
A separate grounding system conductor must extend uninterrupted from the main service panel ground to the scale

to protect load cells and scale wiring from lightning and other transient damage. This ground wire conductor must

be an unsheathed #10 copper wire or larger. Run the bare ground wire conductor intact from the AC power ground

rod to the scale in a separate trench. Bring the wire up from the trench near the junction box and attach it to the

ground lug of the junction box. A #10 bare ground wire is run from the ground lug of the junction box to one of the

junction box mounting studs on the scale frame, thus grounding the scale frame to the same single-point ground as

the AC power for the indicator.

To DC Protection Ground
Connection before Indicator

10 ga. Bare Ground Wire

Ground Lug

R41

JP17

JP7

R52

R50

R40

R24

R14

R15

JP20

JP10

R26

R5

1

R49

R47

JP16

R45

R43

JP9

R23

R21

JP6

JP8

R17

R38

R36

R34

JP11

R32

R30

R28

R10

R8

JP1

R4

R2

R33

JP12

JP2

VR9

JP19

R48

VR7

JP18

R42

R44

R22

R25

R16

R18

VR

2

R19

R39

VR10

R35

R3

7

VR11

R27

R29

R31

R9

R11

R12

R1

R3

R5

VR

5

R6

JP5

JMP/NEG

JMP/POS

VR8

VR

3

VR1

VR12

VR

6

J1

VR4

J2

R13

R7

EXPANSION/J9

J5

ARC

R46

JP4

JP3

ARGND

JP14

JP15

JP13

L3

L4

L2

J8

J4

J3

J6

L1

R20

J7

INDICATOR/J10

JP

TRIM

TRIM

TO

-EX

+EX

+SI

-EX

+EX

+SI

-EX

+EX

1

+SI

-EX

+EX

+SI

JP

JP

TO

SIGNAL

2005

SIGNA

L

CU

T

TO

DISABL

E

CUT

CELL#

CELL#

CELL#

SHD

1

SHD

-SI

1

-SI

SHD

-SI

1

-SI

SHD

SIGNAL

CU

T

TO

CUT

SECT#

DISABL

E

CELL#

CELL#

SIGNAL

SIGNAL

SIGNA

L

D

L

D

DISABL

E

CELL#

SECT#

DISABL

E

CELL#

RICE LAKE WEIGHING SYSTEM

S

JP

-EX

+EX

+SI

-EX

+EX

+SI

-EX

+EX

+SI

-EX

+EX

+SI

SIGNAL

TRIM

TRIM

TRIM

TRIM

TRIM

TRIM

Assembly

-EX

-EX

+EX

+SI

SHD

1

SHD

-SI

1

-SI

1

-SI

SHD

1

-SI

SHD

CONNECT BOTH SHUNTS

TO APPLY SIGNAL

SECT#

SIGNA

L

SIGNA

L

SIGNA

L

CELL#

PN Rev.

+SI

-SI

-SI

SECT#

+SEN

SHD

+SEN

SHD

DISCONNECT BOTH SHUNTS

TO REMOVE SIGNAL

+EX

-SEN

-SEN

CUT TRACE TO ISOLATE SENSE LINE

Transient Board Connectors

Grounding Lug

Figure 3-3. Junction Box Ground Wire Connections.

Note

The scale frame must be connected with 10 ga. wire to the ground lug of the transient protection board inside
the junction box.

Scales with more than one junction box require ground straps to be installed between modules. In addition, all junction
boxes need to be connected to the scale frame.

The final ground wire connection must be at the AC power supply ground terminal or ground rod.