Rice Lake SURVIVOR PL Rail Scale User Manual

Page 9

Advertising
background image

Wooden setting
block

Installation

5

Figure 2-5. Weighbridge Module on Setting Blocks

8. Using a jack and shims, level the module and set its elevation between 2 1/8” and 2 1/4” above concrete

approaches.

Figure 2-6. Module Elevation

9. Using leveling bolts, raise and level the load cell assemblies to contact the upper mount bearing plates.

Jack

Load cell
leveling bolts

Upper load cell
mount plate

Figure 2-7. Load Cell Assembly

10. Jack the weighbridge to allow removal of setting blocks and shims.
11. Install lower base plate washers and nuts.

Note

Do not torque nuts until after plates are grouted.

12. Install check rods and hardware. Set check rods level with a horizontal plane to within +/- 2 degree.