4

Summit 3000 Installation Manual

Lift the scale only with a properly designed spreader bar as shown in Figure 2-1.
Lifting force must be vertical to avoid bending the eye bolts.

Eye bolts must always be inserted into the top of the scale. Lifting should always occur with
the top plate facing up and the eye bolts securely attached through the nuts welded to the
bottom side of the top plate. Lifting from the bottom of the plate could cause nuts to break
loose and the scale to fall.

2.4

Assembly

The following paragraphs give instructions for installing and adjusting the scale feet and anchor plate.

2.4.1

Installing and adjusting feet

For load cell protection during shipping, the scale feet are shipped separately from the floor scale.
Screw one foot into each load cell and turn all the way in until the foot touches either the load cell or the

underside of the deck. Then unscrew each foot three complete turns.
Place a spirit level on the deck. Adjust any “high” corners not in contact with the floor by further unscrewing the

feet on those corners until they just contact the floor surface. When all feet are in contact with the floor, check the

deck with the spirit level to be sure the scale is within 1/4 inch of level.

2.4.2

Anchor Plate Installation

For permanent applications, the scale should be secured to the floor to prevent sideways movement. Two mild

steel floor anchor plates, with holes that slightly exceed the foot diameter, are available as an option for that

purpose.
Lift the scale so that the feet are approximately one inch off the floor. Slide mounting plates under two diagonally

opposed feet. Lower the scale back to the floor, and position the plates as shown in Figure 2-2 so that the

boltdown holes are accessible from above.
Using the mounting plates as templates, drill pilot holes into the floor for suitable anchor bolts. Bolt the plates to

the floor using 1/2-in anchor bolts. Recheck foot adjustment and deck level after this operation.

Note: For installations using access ramps, mounting plates are not necessary as the ramps have built-in mounting plates to
secure the scale feet.

Figure 2-2. Anchor Plate Installation

2.5

Electrical Interface to Indicator

Twenty feet of 6-wire cable to connect the scale to the weight indicator is supplied with each scale. The junction

box is easily accessible through a top access plate located on the top of the Summit 3000. Use the following steps

to wire up the junction box.

1. Remove the four screws using an allen wrench.
2. Slide the junction box assembly out of the deck.
3. Open and remove the top of junction box.
4. Push the cable end into the junction box through a cord grip.
5. Connect the wires to the indicator terminal (Figure 2-3) as shown in Table 2-1.
6. Pull out excess and tighten the cord grip to hold the cable snugly.

Important

WARNING

3.50"

.56" DIA (2K–10K models)

ANCHOR PLATE

SCALE DECK

FOOT

Advertising