Central, Cb901-1, Ring-master – Ring Communications CB901EX User Manual

Page 40: Centralized power supply, Remote power supply

Advertising
background image

CB901EX Operations Manual March 2011

Page 40 of 77

Ring-Master

Central

POWER UNIT

1 2 3 4

1 2 3 4

In station AA916/AA960:

Audio and signalling, wire 5&4
Power, wire 3(+) & 6(-).

In all other stations:

Audio and signalling, wire 1&2
Power, wire 3(+) & 4(-).

CENTRALIZED POWER SUPPLY

Distance max. 350 meter (0.6 mm diam.)

1 2 3 4

Audio and signalling, 1&2 / 5&4.

REMOTE POWER SUPPLY

Distance max. 2000 meter, (0.6 mm diam)

REMOTE POWER UNIT

+ -

CB901-1

F

1

2

3

4

5

6

7

8

9

0

#

M

T

X

INTERCOM

1

2

3

4

5

6

7

8

9

T

0

X

5 9

5 4 3 6

Hirschmann, 6 pin

RJ 45, 8 pin

AA904

AA916/AA960

F

1

2

3

4

5

6

7

8

9

0

#

M

T

X

1

2

3

4

5

6

7

8

9

T

0

X

5 9

AA904

AA916/AA960

In station AA916/AA960:

Audio and signalling, wire 5&4
Power, wire 3(+) & 6(-).

In all other stations:

Audio and signalling, wire 1&2
Power, wire 3(+) & 4(-).

1 2 3 4

5 4 3 6

INTERCOM

PIN 1

PIN 8

MODULAR JACK ASSEMBLY RJ45

FRONT VIEW

Pin1

Pin3

Pin5

Termination to installation cable:
Stations using 6 pin Hirschmann plug:
AA904, AB911, AB917, AB918
and AB919.

Termination to installation cable:
Stations using 8 pin modular RJ45 plug:
AA916/AA960

Pin 1:

wire 1, audio & signalling

Pin 2:

wire 2, audio & signalling

Pin 3:

wire 3, power 24VDC, (+)

Pin 4:

wire 4, power 24VDC, (-)

Pin 5:

external loudspeaker

Pin 6:

external loudspeaker

Pin 1:

external loudspeaker

Pin 2:

external loudspeaker, remote output

Pin 3:

wire 3, power 24VDC (+), remote input

Pin 4:

wire 2, (B), audio & signalling

Pin 5:

wire 1, (A), audio & signalling

Pin 6:

wire 4, power 24VDC, (-)

Pin 7:

remote output

Pin 8:

remote input

R i n g - M a s t er

Central

POWER UNIT

CB901-1

R i n g - M a s t er

Hirschmann, 6 pin

RJ 45, 8 pin

Advertising