Caller id, Device type – Ring Communications CB901EX User Manual

Page 61

Advertising
background image

April 2012 Operations Manual CB901EX

CALLER ID

Each subscriber in the system has 12 alphanumeric characters for identification. This ID is

available for display on the called station (DAD104) and for Event Logging (DNA100). Default is all
spaces.

PROGRAMMING

The following commands are used for this feature:
SCID

Set Caller ID

LCN

List Call Number

Example: Set Caller ID for call number 14 to “Lobby”.

>SCID

cr

Call Number <10-99/*> : 14

cr

Caller ID <alphanumeric> : Lobby

cr

>LCN

cr

Call Number <10-99/*> : 14

cr

Line Call In Priority Network Address Remote
Equ. Number Caller ID Type QUE Alarm Call Display Printer Video NET LEQ
==== ========= ========== ==== ==== ===== ==== ======= ======= ===== === ===
$04 14 Lobby ICM RING 1 5 ... ... ... ... ...
>

DEVICE TYPE

The device type defines the operation of intercom stations.

Type0 = Undefined
Type1 = SUB (DC shift substation)
Type2 = ICM (Master station or substation using speed-dial)
Type3 = PTT (Telephone line)
Type4 = TIE (Intersystem Tie-line)
Type5 = REM (Remote subscriber)
Type6 = ILK (Interlink)
Type7 = DAM (Direct Acces Master)

PROGRAMMING

The following commands are used for this feature.
SDT

Set Device Type

LCN

List Call Number

>SDT

cr

Page 61 of 77