INSTALLATION

The PCB1019 has a one RS485 bidirectional port for communication with Crisis Alert Devices:

DNA100

Used for programming or for interfacing to Log Printer

DNA200

Camera switcher Interace

DNA300

Computer Control Interace

DNA400

Pocket Page Interace

DAD104

Annunicator Display

DS16

Direct select Annunciator, 16 line

The DNA100 can be connected directly to J1 for programming.

The PCB1019 has 3 LEDs for displaying network communication:

M

Master LED. This LED is ON if the EX901 is the Master on the Network.

T

TX Data.

Blinks when EX901 transmit to the network.

R

RX Date.

Blinks when other devices transmit to the network.

SWITCH PROGRAMMING

SW2 on PCB1019 is the crisis alert network address.

Network 1 Node 0 is normally used (Address $08):

1

2

3

4

5

6

7

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

SW4 on PCB1019 is used for selecting number of digits in call numbers when the system is defaulted.:

1

2

OFF

OFF

Special preprogrammed configuration (Reserved)

OFF

ON

2 Digit Dialing (10-55)

ON

OFF

3 Digit Dialing (100-155)

ON

ON

4 Digit Dialing (1000-1055)