Drain pan, filter changes, or other services, System filter service, Empty used tank – Symtech ATF 1 User Manual

Page 15

Advertising
background image


14

5.

Select Dipstick Mode

6.

Enter total amount of fluid to be exchanged

7.

Select Drain Pan mode, Extract fluid

8.

When resume REFILL light comes on, press RESUME REFILL mode, process will replace

fluid extracted

9.

DIPSTICK Mode LED will flash. START VEHICLE. After starting vehicle, Press DIPSTICK

button to begin automatic fluid exchange. A twenty (20) second timer will begin to inter mix
new fluid with used fluid. After timer delay, a repeated cycle will begin where 1.6 quarts of
fluid will be extracted and replaced until total amount of fluid selected in Step 4 has been
exchanged. After each extraction and addition, a ten (10) second delay will occur to inter mix
new and used fluid for the most efficient exchange.

10.

After exchange has been completed, CHECK FLUID LEVEL. If Addition, or Removal of

fluid is required, press DIPSTICK button, then press ADD FLUID or REMOVE FLUID
button. “Default ADD / REMOVE is .5 quart.” Toggle the Plus (+) or Minus (-) buttons to
desired amount, then press appropriate ADD FLUID or REMOVE FLUID button to begin
process to bring fluid level to correct operating level.


Drain Pan, Filter Changes, or Other Services

The DRAIN PAN feature allows the operator to perform filter changes or other service work on the
transmission. This feature should be performed in DIPSTICK mode only for safest performance of
service. The DIPSTICK mode is described above on pages 10~12 as part of the DIPSTICK exchange
process.

System Filter Service

System Filter Service should be performed every 20 to 25 services. The steps for cleaning and
maintaining the filter are as follows…

1.

Power off unit.

2.

Ensure that no pressure from the vehicle is present in the system.

3.

Locate the filter on back of ATF1 just below the cord caddy.

4.

Unscrew the filter bowl and remove.

5.

Remove filter screen.

6.

Clean filter screen using evaporative solvent.

7.

Replace filter screen and bowl.

8.

Resume normal operation


Empty Used Tank

The EMPTY USED function is used to empty used transmission fluid into a bulk waste fluid storage
tank for proper disposal. Depressing the EMPTY USED button on the control panel starts the process
and the flow can be controlled with the manual ball valve at the end of the yellow hose. The internal
pump is equipped with an internal pressure switch that shuts off the pump should blockage or “dead-
heading” occur.

The USED TANK level sensor will end the process automatically when tank level nears zero in tank.
Also, depressing the STOP button on control panel will stop the process.