Control panel descriptions and functions – Symtech ATF 1 User Manual

Page 8

Advertising
background image


7

Control Panel Descriptions and Functions

The following information is intended to familiarize the

ATF1operator with the control panel and its

functions. It is not designed to replace the guidelines and safety warnings found in the remainder of
this document. The complete Operations Manual and Warnings must be read and understood before
operating the machine.


The NEW tank values and functions are displayed and performed on the top left of the panel, while the
USED tank values and functions are displayed and performed on the top right of the panel. (See page 5)

There are two modes of service that can be performed, COOLER LINE mode on the left side of the
control panel and DIPSTICK mode on the right side. The exclusive EXCHANGE START function is
also on the left, while the shared functions between both modes of operation are located down the
middle of the control panel.








The operator starts at the top and works down the control panel. Look at the display upon power up to
view tank levels, to select mode of operation (COOLER LINE or DIPSTICK), to adjust Quart/Liter
amounts of fluid as required, to start functions to be performed, to verify function completed, and to
continue to the next function if needed.

1.

NEW Fluid digital display – Displays the amount of NEW transmission fluid in the NEW

tank when no modes are selected. It also displays the amount of fluid to be exchanged,
added, removed, or the decreasing amount of NEW fluid being pumped from the unit.
Amounts are displayed to the nearest tenth in quarts or liters dependent upon unit of measure
selected.

The display decreases in value for the NEW fluid being pumped out of the unit and
increases in value as the desired fluid amounts are keyed in or set for the various functions.

2.

USED Fluid digital display – Displays the amount of USED transmission fluid in the

USED tank when no modes are selected. In all modes and functions, the USED fluid
display indicates increasing amounts of fluid being extracted from the vehicle during the
process selected. Amounts are displayed to the nearest tenth in quarts or liters dependent
upon unit of measure selected.

The display decreases in value for the USED fluid being pumped out of the unit and
increases in value as the desired fluid amounts are keyed in or set for the various functions.

3.

“+“Increase Button – Adjustment button used to increase the amount of fluid, in tenths, of

a quart/liter to be transferred in each applicable mode and function.

4.

-“Decrease Button – Adjustment button used to decrease the amount of fluid, in tenths, of a

quart/liter to be transferred in each applicable mode and function.

Failure to follow these instructions could endanger the operator and risk damage
to the vehicle.

Exchanges

Decide which mode of exchange will be performed, either the traditional COOLER
LINE mode or the DIPSTICK mode. This unit allows the service technician or the
customer to decide what mode of service will be performed and it is fully capable of
performing the various functions required in either mode.

Advertising