Symtech ATF 1 User Manual

Page 9

Advertising
background image


8

5.

POWER – Indicates that 12V DC power with a negative ground, either internally via

onboard battery, or externally via power cables, has been supplied to the unit through the
Main Power switch.

6.

STOP – Button used to stop all modes and functions at any time. NOTE: If unit is stopped

during an exchange, all exchange amounts will be lost.

7.

“ Q/L ” QUARTS/LITERS – Selection button and indication LED’s used to select and

depict the required unit of measure for volume measurements. Can only be utilized before
mode selection.

8.

COOLER LINE – Mode selection button and indicator LED used to select and depict the

COOLER LINE mode of operation. This mode is selected when intercepting transmission
cooler lines to exchange, extract, and replenish fluid through the vehicle’s transmission
cooler lines. (COOLER LINE can only be selected when pressure from the vehicle is
detected)

9.

EXCHANGE START – Function selection button and indicator LED used only in the

COOLER LINE mode in order to start the exchange of new transmission fluid for old
transmission fluid through the vehicle’s transmission cooler lines.

10.

REVERSE POLARITY – Light that indicates that the battery connections to the vehicle

are reversed and that they need to be corrected before the unit will receive external power.
A continuous alarm accompanies the light as long as the incorrect connection exists.

11.

READY – Illumination of the READY light indicates that the unit has completed the

selected function and will require attention or input from the operator in order to continue.
The READY light is accompanied by short beeps or continuous alarms, depending upon the
function completed, in order to further alert the operator.

12.

DIPSTICK - Mode selection button and indicator LED used to select and show the

DIPSTICK mode of operation. This mode is selected when using the vehicle’s dipstick tube
to exchange, extract, add transmission fluid with the

ATF1unit.The transmission filter can

be serviced at this time as well.

13.

EMPTY NEW – Function selection button and indicator LED used to start and shows when

NEW transmission fluid is being pumped from the unit. Selection of this function empties
the new fluid out through the RED hose, and stops when the tank level nears zero. See page
13 for complete instructions.

14.

LOW TANK LEVEL – LED that indicates when the NEW tank fluid quantity is

inadequate to perform the selected function, or that the NEW tank level is below one quart.
The appropriate amount of new fluid must be added to the NEW tank when this LED is lit.

15.

DRAIN PAN – Function selection button and indicator LED used to start and depict when

draining the vehicle’s transmission sump via the DIPSTICK mode.
The LED lights and remains lit in DIPSTICK mode until function is complete.

16.

RESUME REFILL – Function selection button and indicator LED used to start and depict

the refilling of the vehicle’s transmission sump after a DRAIN PAN procedure has been
performed. The LED lights to prompt operator and remains lit until the process is complete
in DIPSTICK mode.

Advertising