Installing the condensate drain connection, Installing the drain line, Priming the drain trap – Wine Guardian Ducted Split Wine Cellar Cooling Systems (WGS175) - Manual User Manual

Page 33

Advertising
background image

35

Installing the Condensate Drain Connection

The Wine Guardian unit provides dehumidification for the inside of the wine cellar. It cools
the air down to the dew point corresponding to the temperature setpoint of the remote interface
controller. If the vapor barrier of the wine cellar is poorly constructed or excess moisture is in
the basement, the unit may remove excessive amounts of moisture from the wine cellar. The
moisture appears in the condensate drain of the unit.

NOTE: If moisture becomes excessive, install a room type dehumidifier to
dehumidify the basement so as to not overload your Wine Guardian.

Installing the Drain Line

 The drain line must extend from the unit to an external drain or disposal site.
Do not use drain tubing any smaller 1.25cm inside dimension on the unit.

 Splice the drain extension onto the drain outlet with a sort piece of one-half
inch copper tubing and secure with clamps.

 If no drain is available, use a bucket. Do not extend the drain below the rim of
the bucket. Empty the bucket periodically.

The Wine Guardian unit is provided with a built-in drain trap. The drain trap creates a water
seal to prevent air from backing up into the drain pan and causing the drain pan to overflow.
Do not create secondary traps in the external drainline.

Allow enough height for the drain line to function properly. If draining into a nearby sink, the
unit must be elevated higher than the rim of the sink in order for the water to drain by gravity.
Install with a one-quarter inch per linear foot of pitch. Do not tie the condensate drain line
directly into the sanitary sewer system. See Accessories and Optional Equipment on page 10
for information about the condensate pump.

Priming the Drain Trap

The internal drain trap primes itself automatically once the unit has run for a period of time
and after the unit cycles off. This can be confirmed by water dripping from the drain.

Advertising