Wine Guardian Ducted Split Wine Cellar Cooling Systems (WGS175) - Manual User Manual

Page 54

Advertising
background image

56

Advanced Settings--
Advanced Settings -
Special access required.
Contact Wine Guardian
Service Department for
access code

Setting 8

Press “Settings” button to advance to Setting 8.

Press the up or down arrow buttons to adjust
number to the access code. Press “Mode” button
to continue onto setting 9 through 19

.

Compressor anti-short
cycling time

Setting 9

Press “Settings” button to advance to Setting 9.

Press the “Up” or “Down” arrow buttons to adjust
to the desired time in one (1) minute increments.
Maximum is 10 minutes, minimum is 0 minutes.

Compressor anti-short cycling time is the amount of
allowable time between compressor stop and restart.
Rapid start/stop of compressors can cause premature
failure. Factory default is 5 minutes.

WINE GUARDIAN DOES NOT RECOMMEND
SETTINGS LOWER THAN FACTORY
DEFAULT.

Set up remote sensor
or thermostat

Setting 10

Press “Settings” button to advance to Setting 10.

Press the “Up” or “Down” arrow buttons to adjust

to the desired setting.

rS = Remote sensor

rI = Remote interface
LI= Local interface – Through-the-wall unit only

A = Averaging – Jumper position within sensors
must be adjusted. See page 27.