STEAM INLET and CONSUMPTION:

UNITS

SP-40/45

Steam inlet size

DN

in

13

1/2

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

1.2

2.4

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

1.4

3.1

Average Steam consumption per cycle

kg

lbs

23

50.6

STEAM INLET and CONSUMPTION:

UNITS

SP-60/65/75

Steam inlet size

DN

in

13

1/2

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

1.5

3.2

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

1.8

4

Average Steam consumption per cycle

kg

lbs

31

66

STEAM INLET and CONSUMPTION:

UNITS

SP-100/110

Steam inlet size

DN

in

20

3/4

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

2.5

5.5

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

3.4

7.4

Average Steam consumption per cycle

kg

lbs

60

132

STEAM INLET and CONSUMPTION:

Units

SP-130/135

Steam inlet size

DN

in

25

1

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

3.1

6.8

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

4.4

9.6

Average Steam consumption per cycle

kg

lbs

74

163

STEAM INLET and CONSUMPTION:

Units

SP-155/165

Steam inlet size

DN

in

25

1

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

3.8

8.4

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

5.8

12.76

Average Steam consumption per cycle

kg

lbs

88

194

STEAM INLET and CONSUMPTION:

Units

SP-185/195

Steam inlet size

DN

in

25

1

Required steam to heat bath 10F (5.55C)LOW

kg

lbs

5

11

Required steam to heat bath 10F (5.55C)HIGH

kg

lbs

7.7

16.9

Average Steam consumption per cycle

kg

lbs

117

194

Table 4.7: Steam Service Connection Detail

35

Advertising