4 electrical connections, Psenopt advanced rx muting – Pilz PSEN op4F-A-14-180/1 User Manual

Page 25

Advertising
background image

OPERATING MANUAL

PSEN op4F/H-A series

1003067-EN-02

25

4 ELECTRICAL CONNECTIONS

18-pin rectangular pigtail cables are used at the light curtain for electrical connections. The
pigtail cable has M12 connectors with a different number of pins on the opposite side.
On muting models, the receiver is equipped with one 12-pin M12 connector and one 5-pin
M12 connector.
On blanking models, the receiver is equipped with one 12-pin M12 connector.
The transmitter has one 5-pin M12 connector (on both muting and blanking models).
After removing the cap shown in grey (see Fig.) the cables must be connected at the bottom
of the light curtain (the end with LEDs and buttons).


Make sure that the terminator cap (see Chapter 13) is connected on the top of the light
curtain. If this connection is missing, the Master and Slave units will switch to a critical
communication state.

NOTE: The RX connections on the 12-pin M12 cable for the muting model and
the 12-pin M12 cable for the blanking model are different, so it is important to
use the right cable for each configuration (connector with two M12s for the
muting configuration and one M12 for the blanking configuration).


PSENopt Advanced RX Muting

18

pin

M12 12 pin

M12 5 pin


M12 12-Pin:
1. 24 V (brown)
2. 0 V (blue)
3. RESET/RESTART/ALIGN (white)
4. OVERRIDE1 (green)
5. OSSD2 (pink)
6. EDM (yellow)
7. MUTING DEACTIVATION (black)
8. OSSD1 (grey)
9. OVERRIDE2 (red)
10. MUTING LAMP (purple)
11. OVERRIDE STATUS (grey-pink)

12.

EARTHING (red-blue)

M12 5-Pin:

1.

24 V (brown)

2.

MUTING2 (white)

3.

0 V (blue)

4.

MUTING1 (black)

5.

NC (grey)