7.9.7 Blanking mode in the basic configuration

Only a reduced series of configurations can be implemented in basic configuration mode.

BCM configuration: Fixed blanking

P

W

R

O

S

S

D

E

DM

A

CM

LEVEL

1 fixed blanking zone

LED 8 ON green

2 fixed blanking zones

LED 8 OFF

• 1 fixed blanking zone: only 1 zone can be configured as a blanking zone.
• 2 fixed blanking zones: 2 zones can be configured as blanking zones.

BCM configuration: Floating blanking

P

W

R

O

S

S

D

E

DM

A

CM

LEVEL

Floating blanking disabled

LED 6 ON green
LED 7 ON green

Floating blanking 1 beam (with
partial surveillance)

LED 6 ON green
LED 7 OFF

Floating blanking 2 beams (with
partial surveillance)

LED 6 OFF
LED 7 ON green

Reduced resolution 4

LED 6 OFF
LED 7 OFF

• Floating blanking disabled: Floating blanking is not permitted.
• 1 floating blanking beam: The light curtain remains in NORMAL OPERATION if 1 beam

or 0 beams are interrupted.

• 2 floating blanking beams: The light curtain remains in NORMAL OPERATION if 2

adjacent beams, 1 beam or 0 beams are interrupted.

• Reduced resolution 4: The light curtain switches to a SAFE state if more than 4

adjacent beams are interrupted.