7.9.8 Blanking mode in advanced configuration
A maximum of 5 blanking zones (fixed + floating) can be configured in ACM (however, at
least one separating beam is required between the zones).
The user can select the number of beams via ACM.
• Reduced resolution
ACM configuration
The software calculates the maximum object size (in mm) that the light curtain can detect
without triggering a SAFE STATE.
The actual resolution of the light curtain changes based on the varying value that is
assigned to the parameter N.
The safety distance must be calculated based on the actual resolution.
Number of
hidden light
beams
Actual resolution of light curtain
14 mm
30 mm
1
23 mm
49 mm
2
33 mm
68 mm
3
42 mm
87 mm
4
51 mm
105 mm
Actual resolution based on the hidden light beams