1.2.3 Minimum safety distance

The protective device must be positioned at a specific safety distance (Fig. 3), which
guarantees that the operator cannot reach the danger zone until the hazardous machine
movement has come to a standstill by triggering the light curtain.
In accordance with the standard ISO 13855, this distance depends on 4 factors:

• Response time of the light curtain (the time that elapses between the beams being

effectively interrupted and the OSSD contacts opening).

• Machine’s stopping performance (time that elapses between the light curtain contacts

opening and the hazardous machine movement effectively stopping).

• Light curtain’s resolution

• Approach speed of the object to be detected.

Fig. 3 – Safety distance (vertical)

H1 =

≥ 900 mm at a resolution > 40 mm

H2 =

≤ 300 mm at a resolution > 40 mm

S

=

Minimum safety distance in mm