8 DIAGNOSTICS

8.1 Status of LEDs

On the bottom left-hand side of the light curtain 8 LEDs help users to monitor and check the
state of the light curtain in alignment mode, in normal mode and when troubleshooting. The
LEDs can be used to recognise the configuration that has been set via the pushbuttons.
Receiver side (RX):




Meaning of LED

Off

On

Flash

Indifferent

Operating

mode of

light curtain

Information

LED DISPLAY

Suggested action

Alignment

Not aligned

First synchronisation
beam linked

Last synchronisation
beam linked

Minimum signal level

Maximum signal level

Normal

operating

mode

Manual restart

only

Interlock
free beams

User can restart the device by
activating the RESTART in
normal operating mode.

Interlock
interrupted beams

User must clear protected field
before activating the
RESTART.

Normal

operating

mode

OSSD ON
(maximum alignment)

OSSD OFF
Code1

OSSD OFF
Code 2

OSSD OFF
No Code

Signal level at beams

None
Insufficient
Low
Good
Best

EDM active

ACM active

ACM ready for
configuration

Configuration process running
via PC, follow software
instructions

LEVEL

A

C

M

E

D

M

O

S

S

D

s

P

o

w

e

r

Sync

Fault Code

Advertising