9171 Installation Guide

Proprietary & Confidential

Canoga Perkins Metro Ethernet Routing Switch

Page 13 of 26

Fig. 2-5: Grounding Installation Sketch When A Grounding Bar is in Switch Room

Description:

(1) Power input of switch

(2) Ground terminal of switch

(3) Protective grounding cable

(4) Grounding bar of switch room

When there is no grounding bar in the installation environment of Ethernet switches, if a mud field is nearby
and grounding electrodes are permitted to bury, angle steel or steel tube not less than 0.5 m in length may be
used to directly drive into the ground. At this point, the yellow-green PE cables of Ethernet switches should be
connected to the angle steel (or steel pole) by welding, and the soldered joint should be treated with
preservatives.

Fig. 2-6

:Grounding the device through a grounding strip

Description:

(1) Power input of switch

(2) Ground terminal of switch

(3) Protective grounding cable

(4) Ground

(5) Angle steel