7 link status screen, Link status screen -18, Figure 29. diagnostics screen -18 – CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual

Page 38: Figure 30. link status screen -18, Table 9. diagnostics screen definitions -18

Advertising
background image

EdgeAccess Universal Chassis System

DIAGNOSTICS
Local Remote
Chassis/Slot 4/3B 2/5

Loopback Switch Setting: N/A N/A

Loop Test MAC Address: 00 40 2A 80 58 32 00 40 2A 80 58 33

1) Loopback Option Control Software Software
2) Loopback State Disabled Disabled
3) Swap MAC Address
at Loopback Point? Yes Yes
4) Recalculate CRC
at Loopback Point? Yes Yes

Figure 29. Diagnostics Screen

Table 9. Diagnostics Screen Definitions

Selection Description

Loopback Switch Setting

Shows hardware setting only when in a Model 1020; Local,
Remote, or Normal

Loop Test MAC Address

Shows unique MAC address for destination of loopback packets

1) Loopback Option Control Set to Hardware (option for Model 1020 only) or Software

2) Loopback State

Set to Local, Remote, or Clear All Loopbacks

3) Swap MAC Address at
Loopback Point?

Set to Yes or No; use to run loopback packets through a switch

4) Recalculate CRC at
Loopback Point?

Set to Yes or No; use to run loopback packets through a switch

4.7

Link Status Screen

Use the Link Status screen to view the current link conditions on the L357. See Figure 31. To view
link status, follow these steps:

1. From the Main Menu, type

3

, "Link Status," and press <Enter>. The Link Status screen appears.

2. When you finish checking the Link Status, press <Esc> to return to the Main Menu.

LINK STATUS

Local Remote
Chassis 4 2
Slot 3B 5

User Port Link Up Link Up
Extension Port Link Up Link Up

Figure 30. Link Status Screen

L357 Gigabit Ethernet Service Unit

4-18